We have compared the mode I opening critical energy release rate (GIc) measured using the single edge notch bending test and double cleavage drilled compression test on an elastic fragile PMMA and a bulk viscoplastic acrylate used as a glue for wind turbine blades. The study details the experimental procedure, for the crack initiation and […]